Removable partial Denture/Denture cleaning
- Wearing your PPE, place the appliance in a headrest cover, which has been labeled with the patient’s name.
- Take the appliance to the “dry lab” (one on each floor). Cover the appliance with cleaner (tartar and stain remover – which has been properly diluted.
- Place the headrest cover inside a red bag (in case of puncture). Place the red bag inside the ultrasonic unit (which has been filled with water), using the lid to secure the bag.
- Run the ultrasonic for 10-15 minutes (see manufacturer’s instructions on bottle).
- Remove the appliance from the bags and discard the tartar/stain remover solution. Rinse the appliance thoroughly for at least one minute, under room temperature, running water; PRIOR to returning the appliance to the patient.
- A denture brush can be utilized to remove soft debris from the appliance.
NOTE: failure to thoroughly rinse the appliance will result in a burning sensation or bad taste to the patient. If this occurs, have the patient rinse with clear water for 60 seconds, and inform your faculty. Be sure to document this in the patient record.